A shuttered socket outlet has to satisfy two opposing demands. It must open when a real plug is inserted, using the force a person naturally applies. And it must not open when something that is not a plug is pushed into one hole. Both requirements are tested with force, but not the same force, and the numbers are not interchangeable.
The two requirements
Opening for a plug. The shutter must open when the plug is inserted with the specified force, applied through the pins in the normal way. If it needs more force than a typical user applies, the socket is unusable in practice — people will force it, and forcing breaks shutters.
Staying closed against a probe. The shutter must not open when a test probe or a single pin is inserted into one hole. This is the child-protection function: a single object in one hole must not defeat the mechanism.
| Test | Applied how | What a failure looks like |
|---|---|---|
| opening | full plug, all pins together | user cannot insert, or forces it |
| resistance | single probe in one hole | shutter opens, live part reachable |
Why the mechanism can pass one and fail the other
Most shutters work on a two-pin interlock: the earth pin or the two live pins must be pushed together to rotate or slide the shutter out of the way. A single pin cannot produce that motion, which is the whole point.
The failure modes follow from that geometry. A shutter with weak spring force and a light interlock may open on a single probe if the probe happens to catch the actuating edge. A shutter with a strong spring and tight tolerances may need more force than a plug can deliver comfortably, especially as the moulding wears.
Wear moves both numbers in the same direction over time: the mechanism loosens, so it opens more easily for a probe (bad) and needs less force for a plug (also relevant, because a loose shutter can open on one pin). That is why shutter force is worth checking on aged samples, not only new ones.
How the tests are actually performed
The opening test uses a plug gauge inserted at the specified rate, with the force measured or applied by a calibrated device rather than by hand. Hand insertion varies by a factor of two between operators, which is more than the tolerance on the requirement.
The resistance test uses the specified probe, applied to each hole in turn, with the specified force, and the shutter must remain closed. The probe is chosen so that it models a small object — it is not the same probe used for accessibility checks on the enclosure.
Both tests are repeated after the mechanical endurance sequence if the standard requires it, because a shutter that works when new and fails after 10,000 insertions has not met the requirement.
What to write down
For each test: the force applied, the rate of application, the probe or plug used, the condition of the sample (new or after endurance), and the observed result. "Shutter operated correctly" tells a reviewer nothing that can be checked.
One more item that is easy to omit: which hole was tested first. On some mechanisms the first insertion partially loads the interlock, and the second behaves differently. Recording the sequence makes the result reproducible.