A drop rig is a controlled experiment: the plug is released from a known height onto a known face, and the result is repeatable to the millimetre. The rolling drum throws that away on purpose. Inside the barrel the plug lands on whichever edge is next in the rotation, and the damage it accumulates is the kind a plug meets in a toolbox rather than on a laboratory bench.
The test is mechanical. The verdict, as usual, is electrical: the drum does not fail a plug, it creates the conditions under which the dielectric test and the pull test will.
What the apparatus actually does
The barrel is a slowly rotating drum with one internal baffle. Each revolution lifts the sample and drops it, then drags it along the wall. At a few revolutions per minute, a run of 50 tumbles takes about ten minutes and covers the sample roughly evenly. The baffle matters: without it the sample would slide rather than fall, and sliding produces abrasion instead of impact.
| Parameter | Value normally applied | Why it is set that way |
| Tumbles | 50 | Enough for all faces to be hit, few enough to finish in one shift |
| Rotation | About 5 r/min | Slow enough that the fall is free, not thrown |
| Barrel | Steel drum with a single baffle, lined to avoid scratching | The lining prevents the drum itself from being the abrasive |
| Samples | 3 to 5 pieces per run | One piece can miss a face by chance |
| After the run | Dielectric test at the full test voltage for 1 min | Cracks are found electrically, not visually |
| After the run | Pull force and torque re-checked on the cord entry | The gland is the part that moves |
| Acceptance | No crack visible to the eye, no part loosened, dielectric passed | Three conditions, all required |
Fifty is not a magic number, and it is not a life test. It is a sample size: enough impacts that a weak spot shows up, few enough that the test does not become a wear test with an open-ended result.
The four places that fail
- The pin root. The moulded boss around a pin is thin by design. A corner impact puts a bending moment there, and a hairline crack appears on the inside where nobody looks. The dielectric test finds it.
- The earthing pin. It is longer than the live pins, so it takes the first hit every time. A pin bent by 1 mm changes the insertion feel and, on some designs, the contact pressure.
- The shutter. A shutter is a sprung plastic part with a small travel. One impact can knock it off its guide and it will still move, but it will no longer return. Check it by hand after every run.
- The cord entry. The gland is clamped around a cable that is not there. Impact deforms the clamp, and the pull test afterwards is what tells you whether the deformation matters.
Visual inspection catches two of these four. That is why the drum run is always followed by measurements rather than by a photograph.
Comparing labs, and the honest way to report it
Two barrels of the same nominal size will not produce identical impact energies: the fall height depends on the baffle geometry, the lining thickness and how much the sample bounces. When a report says "passed the drum test", the useful number is not the pass, it is the drum and the speed. Ask for both.
A drum result is a screening result. If a design fails it, the design is wrong. If it passes, the design is not yet proven: the moulding, the pin alloy and the gland still have to survive the temperature rise test and the cord anchorage test on the same sample. For the mechanical side of the family, our plug and socket test equipment index lists the drums, drop rigs and impact hammers together so the sequence can be planned in one pass; the clause-by-clause background sits in the technical article list.
Standards referenced: IEC 60884-1 clause 23 (mechanical strength), clause 24 (screws and current-carrying parts), IEC 60068-2-31 for drop guidance.
Running it as a routine check, not a one-off
A drum run costs about 15 minutes including setup, so it is cheap enough to repeat. Three rules keep the results comparable between runs: the same drum, the same 50 tumbles, and the same two measurements afterwards. A plant that changes the drum speed to save time is no longer running the test.
For incoming inspection, a 10-sample run once a month catches tool wear before it reaches the moulding: a 0.05 mm change at the pin boss shows up as a crack in two samples out of ten, while a single sample would pass.
- Log the drum number and the speed with every run.
- Keep the dielectric test at the full 2 kV for 1 minute, not a shortened 1 s version.
- Photograph each sample at 3x before wiping, so the crack is visible in the record.