IPX1 and IPX2 are the two easiest ingress tests to set up badly. Both use a drip box above the specimen, both are described in a few lines of IEC 60529, and both produce a number that looks objective until you ask how the water was actually delivered. The difference between the two levels is not "more water" — it is a different rate, a different duration and, for IPX2, a different orientation of the specimen.
The numbers that define the two levels
Table 8 of IEC 60529 sets the conditions. They are short enough to memorise, and every argument about a drip result starts with one of them:
| Condition | IPX1 | IPX2 |
| Water equivalent | 1 mm per minute | 3 mm per minute |
| Duration | 10 minutes, one position | 2.5 minutes in each of four positions, 10 minutes total |
| Specimen attitude | Normal operating position | Tilted 15 degrees from vertical, rotated 90 degrees between positions |
| Delivery | Drip box, drops falling on the top surface | Same drip box, specimen on a tilting table |
Three millimetres per minute is not three times one millimetre in any useful sense. At 1 mm/min the film on the surface is thin and breaks up; at 3 mm/min it stays continuous and finds gaps that a single-rate test never wets.
Why the rate is usually wrong in practice
A drip box is a tank with a perforated base. The rate is a function of the number of holes, their bore, the head of water above them and, more than most operators expect, how clean the holes are. A box that delivered 1 mm/min when it was new will deliver less once a few holes are partly blocked by scale. The two checks that catch this are cheap:
- Weigh what lands. Put a shallow tray of known area under the box for exactly 60 seconds and weigh the collected water. At 1 mm/min, a 0.1 m² tray collects 100 g in a minute. This converts the whole delivery question into one balance reading.
- Look at the pattern. Drops should be evenly distributed with no dry patch wider than the hole spacing. A dry patch means blocked holes, not a smaller specimen.
For IPX2 the same box is used but the rate is raised to 3 mm/min. Many laboratories do this by adding a second box rather than by increasing head, which is the more repeatable route: head height changes the drop velocity and therefore the splash behaviour at the same time as the rate.
The 15 degree tilt is not cosmetic
IPX2 exists because real enclosures are rarely mounted perfectly vertical. The 15 degree tilt puts water on a surface that would otherwise drain, and the four-position rotation makes sure every side sees it. Two practical points:
- Rotate the specimen, not the box. Moving the drip box changes the drop pattern relative to the holes; rotating the table keeps the delivery identical between positions.
- Start the clock after the first drop lands on the specimen, not when the valve opens. There is a visible lag between opening the supply and the base of the box becoming uniformly wet.
Reading the result without fooling yourself
The acceptance criterion is not "no water inside". It is that water shall not enter in a quantity or in a position that could interfere with normal operation or compromise safety. That leaves judgement, and judgement needs to be recorded before the specimen is opened:
- Photograph the specimen in the chamber, from the same angle every time.
- Wipe the outside dry before opening. Water on the lid runs inward the moment the seal is broken, and that water is then recorded as ingress.
- Distinguish droplets from a pool. A few droplets on an internal wall with no path to live parts is a different finding from a pool sitting on a terminal block.
- Look for the watermark. A dried tide line on an internal surface shows where water actually travelled, which is often more informative than where it ended up.
The condensation trap
The most common false failure in drip testing is condensation, not ingress. If the water in the box is well below the specimen temperature, or if the specimen is switched on and warm, moisture condenses on internal surfaces and is read as leakage. IEC 60529 acknowledges this by requiring the water temperature to be within a few kelvin of the specimen; the practical rule is to let both stabilise in the same room for long enough that a thermometer on the specimen surface and one in the tank read within 5 K.
The opposite error exists too: a specimen that has been sitting in a cold store will condense for the first minutes of the test regardless of the water, so bring it to room temperature first.
A ten point setup check
- Box holes clean and unblocked, pattern even.
- Rate verified by weight, not by the previous report.
- Water and specimen within 5 K.
- Specimen mounted as in service, cable entries fitted as in service.
- Tilting table set to 15 degrees for IPX2 and locked.
- Timer set to 10 minutes total, with 2.5 minute splits marked for IPX2.
- Drain free, so the box does not overflow onto the specimen from the side.
- Specimen photographed before and after.
- External surfaces dried before opening.
- Findings recorded as droplet, film or pool, with location.