The cord anchorage test is one of the few tests in a plug standard where the failure mode is visible if you look for it and invisible if you do not. Nothing breaks. The cord does not pull out. The specimen passes the eye test and then fails on a measurement of two millimetres that nobody took because the jig was tightened by feel.
What the test is actually asking
The requirement behind cord anchorage is mechanical, not electrical: the flexible cable shall not be subjected to tension or twisting at the terminals, and the sheath shall not be pushed into the enclosure. The test reproduces the two loads a cable sees in service — a steady pull when someone drags the appliance by its lead, and a twist when the lead is coiled.
IEC 60884-1 sets out the sequence in its construction requirements, and two numbers carry the whole test:
| Pull force | 60 N, applied 100 times, each application held for about one second |
| Torque | 0.25 N.m, applied for one minute immediately after the pull sequence |
| Displacement limit | The cable shall not be displaced by more than 2 mm at the anchorage |
| Functional limit | No damage to the cord, no strand broken, conductors not moved within their terminals |
The 60 N and 0.25 N.m pair is the mass band for appliances between roughly one and four kilograms. Heavier products are tested at higher values, and a laboratory that applies 60 N to a 6 kg product has run an easier test than the standard asks for.
The measurement people skip
Displacement is measured on the cable sheath relative to the anchorage, before and after. Mark the sheath with a fine line at the point where it enters the grip, and mark the grip body with a matching reference. After the torque stage, measure the offset. A magnifier and a steel rule reading to 0.5 mm is enough; the failure is usually 3 to 6 mm, not 0.3 mm.
If no line is drawn before the test, the inspector has to infer displacement from the position of a moulded rib or a printed legend, and those move with the sheath because they are on the sheath. Draw the line.
Why slip, not breakage, is the usual failure
A cord grip fails in one of four ways, in descending order of frequency:
- Sheath slip. The grip clamps the conductors but not the sheath, so the sheath creeps out under repeated pulls and takes the strain off the clamp while leaving the conductors loaded.
- Grip relaxation. A screwed clamp that was tight on the first pull is loose by the fiftieth because the sheath compressed permanently.
- Cut sheath. The clamp edge is too sharp, and the 60 N pull cuts through the outer sheath over 100 cycles. This passes the displacement check and fails the damage check.
- Terminal movement. The anchorage holds, but the conductors move inside the terminals, which is an electrical failure rather than a mechanical one.
The first two are why the pull is repeated 100 times rather than applied once. A single 60 N pull is a strength test; 100 pulls is a creep test, and creep is what happens in service.
Setup details that change the result
- Clamp the cable, not the plug. The specimen must be held so that the pull is axial. Any side load introduces a bending component that either helps the grip or damages the sheath, depending on direction.
- Apply the force gradually. A snatch load is not what the standard describes and will produce failures that cannot be repeated.
- Torque after pull, not before. The sequence matters: the twist is applied to a grip that has already been worked loose by 100 pulls, which is closer to service.
- Condition first. Cord grips on moulded plugs behave differently at 23 degrees C and at 40 degrees C. Test at the ambient the standard specifies for the test sequence in use.
Reading the result
Three findings are separate and must be recorded separately: displacement beyond 2 mm, damage to the sheath or conductors, and movement of conductors in their terminals. A specimen that passes displacement but shows a cut sheath has failed. A specimen that holds the sheath but has pulled one strand out of a terminal has failed. Collapsing these into a single pass or fail destroys the information that would let the design be fixed.
For the test jigs, the plug and socket gauge range covers the mechanical test accessories that mount a plug square to the pull axis; the full product list includes the torque and pull rigs used with them.